If you require the NSN part BB39, manufactured by Ferranti Electric Inc having CAGE Code 22119 and categorized under FSC 5950 Coils and Transformers under NSN 5950008470457, then look no further than NSN Gamut. Our company, which is owned and managed by ASAP Semiconductor, a distributor in the aerospace and defense industry, has an inventory of over two billion new and obsolete NSN parts, including part BB39 Transformer Power and many more.
At NSN Gamut, we have a strict policy of not sourcing from China, ensuring that all parts you buy from us are completely traceable or sourced directly from reputable manufacturers like Ferranti Electric Inc. Obtain a quote now for BB39. In any case if you don't find your required part submit our straight RFQ and get your part in on time.
Note : We Will Not Share Your Information To Any Third Parties.
We offer a vast range of NSN 5950008470457 parts, including BB39, with quick lead times and competitive prices. NSN Gamut has a large selection of in-demand parts from manufacturers such as Ferranti Electric Inc and others. To speak with a dedicated account manager, just submit an RFQ for BB39 with your basic details like your company name parts quantity required, and get your quote in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-847-0457 Item Description: Transformer Power | 5950 | 008470457 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Bb39 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
POWER | AARG | RELIABILITY INDICATORNOT ESTABLISHED |
POWER | ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3 312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
POWER | ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2 688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
POWER | ABKW | OVERALL HEIGHT6 162 INCHES NOMINAL |
POWER | ACZB | FREQUENCY RATING400 0 HERTZ NOMINAL SINGLE COMPONENT |
POWER | ADAU | BODY HEIGHT5 374 INCHES MINIMUM AND 5 562 INCHES MAXIMUM |
POWER | AEHZ | MAXIMUM OPERATING TEMP65 0 DEG CELSIUS |
POWER | CMLP | THREAD QUANTITY PER INCH32 SINGLE GROUP |
POWER | CWJS | WINDING OPERATING VOLTAGE110 00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
POWER | THSD | THREAD SERIES DESIGNATORUNF SINGLE GROUP |
POWER | TTQY | TERMINAL TYPE AND QUANTITY5 THREADED STUD |
POWER | ACZC | INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
POWER | ACZX | WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
POWER | ADAQ | BODY LENGTH4 187 INCHES MINIMUM AND 4 312 INCHES MAXIMUM |
POWER | ADAT | BODY WIDTH3 563 INCHES MINIMUM AND 3 688 INCHES MAXIMUM |
POWER | AKNA | INCLOSURE TYPEHERMETICALLY SEALED |
POWER | AKPV | MOUNTING FACILITY QUANTITY4 SINGLE GROUP |
POWER | AXGY | MOUNTING METHODTHREADED STUD SINGLE GROUP |
POWER | BPLC | WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
POWER | CQJX | NOMINAL THREAD SIZE0 190 INCHES SINGLE GROUP |
POWER | CRBZ | WINDING OPERATING CURRENT1 8 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY AND 2 3 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |