If you require the NSN part P3524, manufactured by Geotronic Labs Inc having CAGE Code 15815 and categorized under FSC 5950 Coils and Transformers under NSN 5950005491969, then look no further than NSN Gamut. Our company, which is owned and managed by ASAP Semiconductor, a distributor in the aerospace and defense industry, has an inventory of over two billion new and obsolete NSN parts, including part P3524 Transformer Power and many more.
At NSN Gamut, we have a strict policy of not sourcing from China, ensuring that all parts you buy from us are completely traceable or sourced directly from reputable manufacturers like Geotronic Labs Inc. Obtain a quote now for P3524. In any case if you don't find your required part submit our straight RFQ and get your part in on time.
Note : We Will Not Share Your Information To Any Third Parties.
We offer a vast range of NSN 5950005491969 parts, including P3524, with quick lead times and competitive prices. NSN Gamut has a large selection of in-demand parts from manufacturers such as Geotronic Labs Inc and others. To speak with a dedicated account manager, just submit an RFQ for P3524 with your basic details like your company name parts quantity required, and get your quote in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-549-1969 Item Description: Transformer Power | 5950 | 005491969 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
P3524 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CRMJ | WINDING POWER RATING | 2.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY17.16 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY99.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 99.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | 2 PRIMARY WINDINGS; 5 SECONDARY WINDINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.031 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP5.031 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.571 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.571 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.202 INCHES MINIMUM SINGLE GROUP AND 0.202 INCHES MINIMUM SINGLE GROUP AND 0.208 INCHES MAXIMUM SINGLE GROUP0.208 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 6.000 INCHES MAXIMUM6.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.938 INCHES MAXIMUM3.938 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.375 INCHES MAXIMUM3.375 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 20.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 660.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 0.1 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY2.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 126.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 17.16 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY126.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |