If you require the NSN part 101215, manufactured by Jeffers Electronics Inc having CAGE Code 59474 and categorized under FSC 5905 Resistors under NSN 5905001063818, then look no further than NSN Gamut. Our company, which is owned and managed by ASAP Semiconductor, a distributor in the aerospace and defense industry, has an inventory of over two billion new and obsolete NSN parts, including part 101215 Resistor Network Fi and many more.
At NSN Gamut, we have a strict policy of not sourcing from China, ensuring that all parts you buy from us are completely traceable or sourced directly from reputable manufacturers like Jeffers Electronics Inc. Obtain a quote now for 101215. In any case if you don't find your required part submit our straight RFQ and get your part in on time.
Note : We Will Not Share Your Information To Any Third Parties.
We offer a vast range of NSN 5905001063818 parts, including 101215, with quick lead times and competitive prices. NSN Gamut has a large selection of in-demand parts from manufacturers such as Jeffers Electronics Inc and others. To speak with a dedicated account manager, just submit an RFQ for 101215 with your basic details like your company name parts quantity required, and get your quote in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-106-3818 Item Description: Resistor Network Fi | 5905 | 001063818 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
101215 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPP | ELECTRICAL RESISTANCE | 1.109 KILOHMS 1ST INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 1.500 KILOHMS 2ND INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 10.504 KILOHMS 9TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 100.000 KILOHMS HIGHEST RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 13.815 KILOHMS 10TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 18.000 KILOHMS 11TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 2.264 KILOHMS 3RD INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 2.500 KILOHMS 4TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 26.595 KILOHMS 12TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 34.000 KILOHMS 13TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 4.500 KILOHMS 5TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 4.753 KILOHMS 6TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 48.000 KILOHMS 14TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 5.000 KILOHMS 7TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 548.000 OHMS LOWEST RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 85.144 KILOHMS 15TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 9.000 KILOHMS 8TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 93.100 KILOHMS 16TH INTERMEDIATE RESISTANCE VALUE |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -0.250/+0.250 EACH RESISTOR |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 90.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARA | TERMINAL QUANTITY | 23 |
AARB | TERMINAL TYPE | TERMINAL TYPE PER BODY STYLE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.375 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 2.600 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.125 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.375 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.0001 EACH RESISTOR |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 12TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 14TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 15TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 1ST INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 2ND INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 3RD INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 4TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 6TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 7TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 9TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 LOWEST RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 12 HIGHEST RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 2 10TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 2 13TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 2 16TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 3 11TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 3 5TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 4 8TH INTERMEDIATE RESISTANCE VALUE |
STYL | STYLE DESIGNATOR | DUAL INLINE |
TEST | TEST DATA DOCUMENT | 88818-C600012525 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING D |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote